Aktuelle Forschungsprojekte

Image Non- invasive flow measurements
Image Ionocaloric cooling
Image Energy efficiency consulting - cogeneration systems
Image 3D - Air flow sensor
Image Influenced melting point of water by magnetic field
Image Refrigerants, lubricants and mixtures
Image Heat2Power
Image Intelligent innovative power supply for superconducting coils
Image Cryostats, Non-Metallic and Metallic
Image Testzentrum PLWP at ILK Dresden
Image Swirl-free on the move...
Image Software for test rigs
Image Humidifier System for High-Purity Gases
Image Calibration leak for the water bath leak test
Image Laseroptical measurement
Image Low Temperature Tribology

You are here:   /  Home


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request