Aktuelle Forschungsprojekte

Image Air-flow test rig for fan characteristic measurement
Image Combined building and system simulation
Image Innovative Parahydrogen Generator Based on Magnets
Image Laseroptical measurement
Image Test rigs for refrigeration and heat pump technology
Image Testing of mobile leak detectors according to DIN EN 14624
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image IN-SITU SWELLING BEHAVIOUR OF POLYMER MATERIALS IN FLAMMABLE FLUIDS
Image Energy efficiency consulting - cogeneration systems
Image Brine (water)-water heat pump
Image Pulse-Tube-Refrigerator with sealed compressor
Image Testzentrum PLWP at ILK Dresden
Image Measurement of insulated packaging
Image Optimizing HVAC operation with machine learning
Image Corrosion inhibitor for ammonia absorption systems
Image Cryostats, Non-Metallic and Metallic

You are here:   /  Home


Low Temperature Tribology

Industry and R&D

Dipl.-Ing. Gunar Schroeder

+49-351-4081-5129

Tribological studies at cryogenic temperatures

For special applications at cryogenic temperatures the use of dry friction is necessary because the working temperatures are significant lower than the working range of liquid lubricants.

The ILK Dresden has extensive experience in the field of material testing at cryogenic temperatures and has developed a measuring system (from roomtemperature down to cryogenic temperatures) to determine the roughness and the coefficient of friction of different sliding material combinations.

The test stand consists of an experimental platform and a traversing mechanism with a force sensor, which is controlled via PC. The direct measurement of the friction force is carried out by the distance covered. Measurements can be performed down to −196 °C (lower temperatures on request). The cooling of the experimental platform and the samples is realised by a controlled liquid nitrogen heat exchanger/evaporator. Measurements are performed under an atmosphere of gaseous nitrogen to prevent the ingress of moisture. Thereby the experimental samples have no direct contact to liquid nitrogen. The uniform temperature distribution is measured by thermocouples, which are calibrated at the ILK Dresden.

Advantages: modular test setup which can be changed to specific requirements; adjustment of sample geometry and/or test track is possible.

Parameter

Measuring accuracyMeasuring range 0.4 N to 2 N≤ 1 % of measured value
Measuring range 2 N to 100 N≤ 0.5 % of measured value
Measuring range extendible up to 5 kN

Repeatability
(e.g. PTFE)

± 0.05 N respectively 1.5 % of coefficient of friction

Your Request

Further Projects