Current research projects

Image Optimizing HVAC operation with machine learning
Image Modular storage system for solar cooling
Image Investigation of material-dependent parameters
Image Micro fluidic expansion valve
Image Testzentrum PLWP at ILK Dresden
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Performance tests of condensing units
Image Calibration leak for the water bath leak test
Image Solar Cooling
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Range of services laboratory analyses
Image Computational fluid dynamics CFD
Image Panel with indirect evaporative cooling via membrane
Image Filter Tests
Image All-in-one device for freeze-drying and production of biomaterial
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids

You are here:   /  Home


Calibration of Low Temperature Sensors

Industry and R&D

Dr. rer. nat. Matthias Schneider

+49-351-4081-5126

According to the comparative measurement method

Accurate and reliable measurements are the requirements for high-quality research and development or industrial production. Using the comparative measurement method the following sensors can be calibrated:

  • Resistance Temperature Detectors (RTD) with positive temperature coefficient (like Platinum or Rhodium-Iron RTDs)
  • RTD with negative temperature coefficient (like Germanium or Cernox™ RTDs)
  • Diode and thermocouples.

With an automatic measuring station several temperatures according to a sample point table will be adjusted. The calibration is carried out with secondary thermometers that are calibrated by an authority. Furthermore a fix point check with LHe or LN2 will be performed. In addition, a calbriated Cernox sensor is available for measurements in the low temperature range. The measuring facility allows the calibration of about 30 sensors at once. There are continuous extensions for different sensor types.

Parameter

IndicatorMinimalMaximal
Measuring range1.5 K350 K
Measuring accuracy5 mK (1.5 ... 4.2 K)50 mK (80 ... 350 K)
Sample dimensioncommon sensor packages
Sample preparationnot necessary

Your Request

Further Projects

Image

Computational fluid dynamics CFD

Scientific analysis of flows

Image

Humidifier System for High-Purity Gases

Nafion - moisture transfer

Image

Behavior of multiphase cryogenic fluids

experimental und numerical investigations

Image

Innovative Parahydrogen Generator Based on Magnets

Magnetic Gas Separation of the Hydrogen Isomers