Image Low Temperature Tribology
Image Helium extraction from natural gas
Image Solar Cooling
Image Micro fluidic expansion valve
Image State of system and failure analyses
Image Pulse-Tube-Refrigerator with sealed compressor
Image Thermostatic Expansion Valves
Image Testzentrum PLWP at ILK Dresden
Image Hydrogen and methane testing field at the ILK
Image Membrane-based Air Conditioning
Image Low noise and non metallic liquid-helium cryostat
Image Test procedures for electrical components
Image High Capacity Pulse Tube Cooler
Image Non- invasive flow measurements
Image Investigation of coolants
Image Low Temperature Measuring Service

You are here:   /  Home


Calibration of Low Temperature Sensors

Industry and R&D

Dr. rer. nat. Matthias Schneider

+49-351-4081-609

According to the comparative measurement method

Accurate and reliable measurements are the requirements for high-quality research and development or industrial production. Using the comparative measurement method the following sensors can be calibrated:

  • Resistance Temperature Detectors (RTD) with positive temperature coefficient (like Platinum or Rhodium-Iron RTDs)
  • RTD with negative temperature coefficient (like Germanium or Cernox™ RTDs)
  • Diode and thermocouples.

With an automatic measuring station several temperatures according to a sample point table will be adjusted. The calibration is carried out with secondary thermometers that are calibrated by an authority. Furthermore a fix point check with LHe or LN2 will be performed. In addition, a calbriated Cernox sensor is available for measurements in the low temperature range. The measuring facility allows the calibration of about 30 sensors at once.

Parameter

IndicatorMinimalMaximal
Measuring range1.5 K350 K
Measuring accuracy5 mK (1.5 ... 4.2 K)50 mK (80 ... 350 K)
Sample dimensioncommon sensor packages
Sample preparationnot necessary

Your Request

Further Projects

Image

Non- invasive flow measurements

PDPA - flow fields and particle sizes

Image

Prüfverfahren für Außenluftfilter

Bewertung von biologisch aktiven Außenluftfiltern

Image

Computational fluid dynamics CFD

Scientific analysis of flows

Image

Textiler Wärme- und Stoffübertrager in KVS-Systemen

Enthalpierückgewinnung zwischen örtlich getrennten Luftströmen


Contact

Institut für Luft- und Kältetechnik - Gemeinnützige Gesellschaft mbH
Bertolt-Brecht-Allee 20, 01309 Dresden


Secretary to the Management

+49-351-4081-520

+49-351-4081-525

Image ISO 9001
Bild Zuse Mitglied Bild SIG