Aktuelle Forschungsprojekte

Image Cryogenic liquid piston pumps for cold liquefied gases like LIN, LOX, LHe, LH2, LNG, LAr
Image Performance tests of refrigerant compressors
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Optimizing HVAC operation with machine learning
Image Lifetime prediction of hermetic compressor systems
Image IO-Scan - Integral measuring optical scanning method
Image Non- invasive flow measurements
Image Intelligent innovative power supply for superconducting coils
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Laseroptical measurement
Image Calibration leak for the water bath leak test
Image Innovative Parahydrogen Generator Based on Magnets
Image All-in-one device for freeze-drying and production of biomaterial
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings

You are here:   /  Home


Low Temperature Tribology

Industry and R&D

Dipl.-Ing. Gunar Schroeder

+49-351-4081-5129

Tribological studies at cryogenic temperatures

For special applications at cryogenic temperatures the use of dry friction is necessary because the working temperatures are significant lower than the working range of liquid lubricants.

The ILK Dresden has extensive experience in the field of material testing at cryogenic temperatures and has developed a measuring system (from roomtemperature down to cryogenic temperatures) to determine the roughness and the coefficient of friction of different sliding material combinations.

The test stand consists of an experimental platform and a traversing mechanism with a force sensor, which is controlled via PC. The direct measurement of the friction force is carried out by the distance covered. Measurements can be performed down to −196 °C (lower temperatures on request). The cooling of the experimental platform and the samples is realised by a controlled liquid nitrogen heat exchanger/evaporator. Measurements are performed under an atmosphere of gaseous nitrogen to prevent the ingress of moisture. Thereby the experimental samples have no direct contact to liquid nitrogen. The uniform temperature distribution is measured by thermocouples, which are calibrated at the ILK Dresden.

Advantages: modular test setup which can be changed to specific requirements; adjustment of sample geometry and/or test track is possible.

Parameter

Measuring accuracyMeasuring range 0.4 N to 2 N≤ 1 % of measured value
Measuring range 2 N to 100 N≤ 0.5 % of measured value
Measuring range extendible up to 5 kN

Repeatability
(e.g. PTFE)

± 0.05 N respectively 1.5 % of coefficient of friction