Aktuelle Forschungsprojekte

Image Lifetime prediction of hermetic compressor systems
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image OVERALL SYSTEM OPTIMIZATION OF REFRIGERATION PLANT SYSTEMS FOR ENERGY TRANSITION AND CLIMATE PROTECTION
Image Micro fluidic expansion valve
Image Electrical components in refrigeration circuits
Image Influenced melting point of water by magnetic field
Image Air-flow test rig for fan characteristic measurement
Image Optimizing HVAC operation with machine learning
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image High temperature heat pump
Image Swirl-free on the move...
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image Non- invasive flow measurements
Image Ice Slurry Generation
Image Certifiable connection types in cryogenics
Image State of system and failure analyses

You are here:   /  Home


Performance tests of condensing units

Industry

Dr.-Ing. Matthias Böhm

+49-351-4081-5211

Does your condensing unit perform well?

The Test center PWLP supports the industry in the development of energy-efficient vapor-compression refrigeration system and compression heat pumps.

The ILK Dresden offers the following services for you:

For a defined application map of air-cooled condensing units, we determine the cooling capacity, drive capacity, COP, etc. The tests are carried out on a refrigeration circuit in combination with a climatic chamber (Fig. 1).

As part of the accreditation of the PLWP according to DIN EN ISO / IEC 17025, the PLWP conducts the investigation of air-cooled condensing units according to the currently applicable measurement standards DIN EN 13771-2:2017-11 and DIN EN 13215:2017-03.

Performance tests in the range 0.7 ... 10 kW can be carried out normatively for evaporation temperatures of -35, -10 to +5°C with air inlet temperatures in the condensing unit of 5, 15, 25, 32 to 42°C (partial load).
Current calibrations of the measuring systems are a matter of course.
Within the scope of our flexible accreditation, further measuring tasks can be realized according to applicable test standards.

The test can be carried out with the refrigerants R134a, R404a, R407C, R410A, R452A. The source of the thermodynamic properties of the refrigerants is the library ASREP from ASERCOM.

Outside accreditation, further services can be offered:

Additional offerings

  • Investigation of map points outside the standard values
  • Measurement of the oil discharge
  • Measurement of the air volume flow
  • Investigation with variable rotation speed (frequency inverter)
  • Sound investigations in the third octave or octave frequency band
  • Measurement of pulsation in pipes

Research and Development

The ILK Dresden has been active in the development and testing of refrigeration and heat pump technology for many years. The development work is carried out individually and in close cooperation with the client. The experiences of the ILK Dresden were and are continuously collected in a multiplicity of research projects.

Various investigations were carried out on the suitability of the standardized test methods within the scope of the project “Test methods and test rigs for condensing units” (BMWi MF 150072, 1.10.2015 - 30.03.2018).

Some results of the project in terms of test rig design and test methodology are:

  • the investigation and confirmation of suitable minimum wall spacing’s for structurally open condensing units (room size and support fan of the room air system)
  • the suitable distribution of sensors for temperature at the air inlet and the influence of condenser geometry on the average inlet temperature in the test room
  • the analysis of the differentiated possibilities of energy-efficient test rig operation through regenerative condenser heat utilisation in the refrigeration circuit of the test rig
  • the requirements and restrictions for automatic measurement of the circulating oil concentration via mass flow sensors.

Your Request

Further Projects

Image

Measurements on ceiling mounted cooling systems

Comparative performance measurement

Image

Micro fluidic expansion valve

for increasing of the efficiency of small and compact cooling units

Image

Solar Cooling

Solar Cooling with Photovoltaic

Image

Hydrogen and methane testing field at the ILK

Simultaneously pressures up to 1,000 bar, temperatures down to –253°C

Image

Low noise and non metallic liquid-helium cryostat

Low-noise Magnetic Field Cryostat for SQUID-Applications