Aktuelle Forschungsprojekte

Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Filter Tests
Image Air-flow test rig for fan characteristic measurement
Image Calibration of Low Temperature Sensors
Image Cryogenic liquid piston pumps for cold liquefied gases like LIN, LOX, LHe, LH2, LNG, LAr
Image Laseroptical measurement
Image Service offer for Leak Detection and Tightness Test
Image Intelligent innovative power supply for superconducting coils
Image Measurement of insulated packaging
Image Helium extraction from natural gas
Image Humidifier System for High-Purity Gases
Image Hydrogen and methane testing field at the ILK
Image Brine (water)-water heat pump
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Refrigerants, lubricants and mixtures
Image Pulse-Tube-Refrigerator with sealed compressor

You are here:   /  Home


State of system and failure analyses

Industry

Dr.-Ing. Matthias Böhm

+49-351-4081-5211

Cause of the failure unknown?

We support the industry in the development of energy-efficient vapor-compression refrigeration system and compression heat pumps.

The ILK Dresden offers the following services for you:

The ILK Dresden has been active in the development and testing of refrigeration and heat pump technology for many years. A focal point of our activities is the condition analyses of refrigeration compressors and the damage analysis of refrigerating plants and heat pumps.

We can pass on our many years of experience in the analysis of different compressor types (Fig. 1) in suggestions and hints for further compressor operation and plant behavior (Fig. 2).

We can offer the following Services:

  1. Condition analysis of refrigeration compressors
  2. Evaluation of damage causes at the compressor
  3. Notes on further operation after sample analysis from the field
  4. Definition of lifetime test programs (500 h) with different stress levels inside and outside the compressor map (liquid, continuous switch, frequency, pressure ratio etc.)
  5. Implementation of these different test programs for the service life of the compressor type on a suitable test rig with subsequent analysis of the refrigerant compressor

Research and Development

The ILK Dresden has been active in the development and testing of refrigeration and heat pump technology for many years. The development work is carried out individually and in close cooperation with the client.

The ILK Dresden has many years of know-how in the investigation of refrigerant compressors.

The necessary know-how for the evaluation of the machines was developed in particular in the funded projects:

  • "Energy efficiency of refrigerant compressors", (BMWi EN FKZ IW073034),
  • "Multi intermediate injection at rotary compressors", (BMWi EN FKZ VF120022)
  • "Procedures for compressor protection" (BMWi EN FKZ MF150165),

In these projects, knowledge was gained in particular on the following topics, which enable a professional interpretation of the results:

  • Constructional design of different compressor designs
  • Gradients for degree of quality and degree of output as function of compressor design and compressor map
  • Knowledge about the behaviour of refrigerating capacity, power absorbed and COP depending on compressor design and operating conditions
  • Relationships between external and internal conditions of the compaction process and effects on the definition of comparative parameters
  • Evaluation of the operating condition-dependent behaviour of the refrigerant/oil mixture in the compressor housing of different compressor types (reciprocating and scroll compressors)
  • Evaluation of the time migration of refrigerant into the compressor during thermally different downtimes

Your Request

Further Projects

Image

Measurements on ceiling mounted cooling systems

Comparative performance measurement

Image

Micro fluidic expansion valve

for increasing of the efficiency of small and compact cooling units

Image

Solar Cooling

Solar Cooling with Photovoltaic

Image

Hydrogen and methane testing field at the ILK

Simultaneously pressures up to 1,000 bar, temperatures down to –253°C

Image

Low noise and non metallic liquid-helium cryostat

Low-noise Magnetic Field Cryostat for SQUID-Applications