Aktuelle Forschungsprojekte

Image State of system and failure analyses
Image Modular storage system for solar cooling
Image Tribological investigations of oil-refrigerant-material-systems
Image High Capacity Pulse Tube Cooler
Image Cryogenic liquid piston pumps for cold liquefied gases like LIN, LOX, LHe, LH2, LNG, LAr
Image Electrical components in refrigeration circuits
Image OVERALL SYSTEM OPTIMIZATION OF REFRIGERATION PLANT SYSTEMS FOR ENERGY TRANSITION AND CLIMATE PROTECTION
Image Non- invasive flow measurements
Image Verification of storage suitability of cryo tubes
Image Test procedures for electrical components
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Cryostats, Non-Metallic and Metallic
Image Swirl-free on the move...
Image Lifetime prediction of hermetic compressor systems
Image Test rigs for refrigeration and heat pump technology
Image Innovative Parahydrogen Generator Based on Magnets

You are here:  Home /  Measurements and Tests


Low Temperature Measuring Service

Industry and R&D

Dr. rer. nat. Matthias Schneider

+49-351-4081-5126

Measurement of Thermal Properties at Low Temperatures

The cool down to cryogenic temperature causes thermal stress within the structure of components or complete devices. Furthermore thermal material properties could change crucial.

Samples can be proved down to 10 K via temperature cycling tests and/or measurements of the thermal conductivity, the coefficient of thermal expansion (also as integral for large sample dimensions) and the heat capacity. An experimental station with optimised conditions for measuring the thermal conductivity of different materials is under construction.

Thermal Tests (Cycling)

IndicatorMinimalMaximal
Cool down rate25 K/h200 K/min
Cool down cycles1Customer preference
Measuring accuracy1 %5 %
 Temperature range80 K (5 K)450 K
Sample preparationCustomer material
Sample dimensionup toØ 400 mm x 550 mm
other  dimenions on request

Thermal Conductivity

IndicatorMinimalMaximal
Measuring range10-2 W/(m K)103 W/(m K)
Measuring accuracy1 %5 %
 Temperature range10 K350 K
Sample preparationCustomer material
Sample dimensionup toØ 60 mm x 20 mm
other  dimenions on request

Heat Capacity

IndicatorMinimalMaximal
Measuring range10 J/(kg K)10 J/(kg K)
Measuring accuracy1 %5 %
Temperature range10 K350 K
Sample preparationCustomer material
Sample dimensionup to150 x 150 x 150 mm3
other  dimenions on request

Coefficient of Thermal Expansion

IndicatorMinimalMaximal
Measuring range10-6 K-110-4 K-1
Measuring accuracy0.1 %5 %
Temperature range10 K350 K
Sample preparationCustomer material
Sample dimensionup to200 x 200 x 200 mm3
other  dimenions on request

Your Request

Further Projects - Measurements and Tests

Image

Cold meter