Image Measurements on ceiling mounted cooling systems
Image Low Temperature Tribology
Image Solar-electric Cooling
Image Laughing gas as an alternativ refrigerant for R-23
Image Helium extraction from natural gas
Image Solar Cooling
Image State of system and failure analyses
Image Thermostatic Expansion Valves
Image Prüflabor Wärmepumpen at ILK Dresden
Image Optimization of pharmaceutical freezing processes
Image Hydrogen test area at ILK Dresden
Image Membrane-based Air Conditioning
Image Components for Cold Storage Systems
Image Natural gas vehicle for long distances
Image Thermal engines
Image Low noise and non metallic liquid-helium cryostat

You are here:  Home /  Measurements and Tests


Thermostatic Expansion Valves

Industry

Dr.-Ing. Matthias Böhm

+49-351-4081-643

Does the TXV function correctly?

We support the industry in the development of energy-efficient vapor-compression refrigeration system and compression heat pumps.

The ILK Dresden offers the following services for you:

The ILK Dresden have been active in the field of performance testing of refrigeration compressors and condensing units for over 10 years.

Since 2013 we have been able to extend our offer to the investigation of thermostatic expansion valves (TEV) with external temperature sensors.

The Tests of the TEV are carried out on a suitable refrigeration cycles (Fig. 2), taking into account the following standards

  • AHRI 750 (2007),
  • ANSI/ ASHRAE 17 (2008, Fig. 1) and
  • ASERCOM-Statement (9_GER_Dimensionierung_von_TXV_2011)

Current calibrations of the measuring systems are a matter of course.

The test can be carried out with the refrigerants R134a, R404A, R407A, R407C, R407F, R448A, R513A, R452A up to a mass flow of 400 kg/h (~20 kW for R134a).

Additional offerings

The following influences on the valve behaviour can be investigated

  • run-in period
  • hysteresis
  • transient tests / time constant
  • pressure losses
  • Sub cooling
  • Ambient temperature
  • Critical pressure ratio

Your Request

Further Projects - Measurements and Tests

Image

Cold meter

The fast way to refrigerating capacity

Image

State of system and failure analyses

Cause of the failure unknown?

Image

Performance tests of refrigerant compressors

Does your compressor perform well?

Image

Performance tests of condensing units

Does your condensing unit perform well?


Contact

Institut für Luft- und Kältetechnik - Gemeinnützige Gesellschaft mbH
Bertolt-Brecht-Allee 20, 01309 Dresden


Secretary to the Management

+49-351-4081-520

+49-351-4081-525

Bild Zuse Mitglied Bild SIG