Aktuelle Forschungsprojekte

Image Software modules
Image Air-water heat pumps
Image Electrical components in refrigeration circuits
Image Certifiable connection types in cryogenics
Image Thermostatic Expansion Valves
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Preformance measurements of heat exchangers
Image Behavior of multiphase cryogenic fluids
Image Innovative small helium liquefier
Image Panel with indirect evaporative cooling via membrane
Image Air-flow test rig for fan characteristic measurement
Image Corrosion inhibitor for ammonia absorption systems
Image Cryogenic liquid piston pumps for cold liquefied gases like LIN, LOX, LHe, LH2, LNG, LAr
Image Calibration of Low Temperature Sensors
Image Swirl-free on the move...
Image Energy efficiency consulting - cogeneration systems

You are here:  Home /  Measurements and Tests


Tribological investigations of oil-refrigerant-material-systems

Dr.-Ing. Margrit Junk

+49-351-4081-5419

Modified Almen-Wieland wear testing machine

The modified Almen-Wieland wear testing machine is used for the determination of the tribological properties of oil-refrigerant-bearing-systems under mixed friction conditions. The interaction of lubricants, additives, refrigerants and materials is tested. On the basis of these investigations refrigeration oils and materials could be preselected, but the tests can not substitute field test with refrigeration machines.

Principle

Two half bearings are pressed hydraulically against a test pin rotating horizontally in the lubricant.

The extreme pressure failure, i. e. the load bearing capacity of oil, is determined by increasing continuously or stepwise the test load until seizure of pin and bearing occurs and the pin breaks. The coefficient of friction and the wear are determined with constant (low) load applied during a prescribed test time.

Specialties

  • Hermetic test cell, which allows testing with refrigerant pressures up to 10 bar.
  • Thermostated test cell for a defined lubricant temperature.
  • Continuous record of fest force, turning moment, pressure of refrigerant, temperature and wear.
  • Use of both Almen-Wieland and half bearings with Falex geometry (dimensions of the V-block than the original Falex bearings according to ASTM D 3233).
  • Adaption of the tribological system by choosing materials of test pins and half bearings.

Our services

  • Evaluation of lubricant-refrigerant-material-systems by load bearing capacity of lubricant (extreme pressure failure load), coefficient of friction, wear, changes of lubricant
  • Evaluation of tribological systems after changing lubricants, refrigerants or bearing materials in order to minimize expensive field tests
  • Failure analysis

 


Your Request

Further Projects - Measurements and Tests

Image

Low temperature – test facilities

thermal cycling tests at very low temperatures

Image

Investigation according to DIN EN ISO 14903

These tests according to DIN EN ISO 14903 are possible at ILK Dresden