Image Low Temperature Tribology
Image Helium extraction from natural gas
Image Solar Cooling
Image Micro fluidic expansion valve
Image State of system and failure analyses
Image Pulse-Tube-Refrigerator with sealed compressor
Image Thermostatic Expansion Valves
Image Testzentrum PLWP at ILK Dresden
Image Hydrogen and methane testing field at the ILK
Image Membrane-based Air Conditioning
Image Low noise and non metallic liquid-helium cryostat
Image Test procedures for electrical components
Image High Capacity Pulse Tube Cooler
Image Investigation of coolants
Image Low Temperature Measuring Service
Image Calibration of Low Temperature Sensors

You are here:  Home /  Research and Development


Brine (water)-water heat pump

Industry

Dipl.-Ing.Ralf Noack

+49-351-4081-649

Test according DIN EN 14511 and 14825

The ILK Dresden has an accredited testing center and offers independent tests for the following certification bodies, organisations or quality labels:

  • EHPA Quality Label Heat Pump
  • CEN Keymark certification
  • Tests according to ErP
  • Verification test of efficiency for state subsidies
    (e.g. BAFA, MCS, Harp)

Various types of brine to water heat pumps are tested in the ILK test center - PLWP. Tests are carried out on

  • fix speed heat pumps
  • variable speed heat pumps
  • heat pumps with special design (direct condensing, with thermal storage, etc.)

The brine (water) water heat pumps are tested on a semi-automatic test rig.

The Testzentrum PLWP is accredited to DIN EN ISO / IEC 17025 for the following performance and sound measurements

  • DIN EN 14511, DIN EN 14825 and DIN EN 16147
  • DIN EN 12102 and DIN EN 9614

Research and Development

We support the industry in its efforts to develop energy-efficient refrigeration systems and heat pumps.

The ILK Dresden has been active in the development and testing of refrigeration and heat pump technology for many years. The development work is carried out individually and in close cooperation with the client. The experiences of the ILK Dresden were and are continuously collected in a multiplicity of research projects.

In recent years, for example, the development of a high-temperature heat pump with operation temperatures above 120 °C has been an important research project.

Within the limits of our flexible accreditation, further measurement tasks can be carried out in accordance with applicable testing standards. Outside accreditation, further services can be offered:

  • Performance testing of WP with storage tanks
  • dynamic power measurements by means of temperature and power profile
  • Investigations of the cooling circuit of the heat pump
  • Expert opinions and evaluations of individual components
  • Characterisation of the operating behaviour of the heat pump
  • Refrigerant and material testing

Short description of test procedure

The measurements of the heat pumps are carried out in accordance with current valid guidelines (ErP) and standards DIN EN 14511 or DIN EN 14825. If required, minor deviations are possible due to our flexible accreditation (see below Annexes to accreditation, p. 3)

The testing of the heating capacity is normally based on the water-enthalpy method. For this, the water mass flow and the temperatures are measured directly at the inlet and outlet of the heat pump. The test points are based on the current guidelines and test standards of certification bodies, quality labels (EHPA guidelines) and current standards.

Heat pumps with fixed-speed compressors and power-controlled heat pumps can be tested. Outside the accreditation of the Testzentrum PLWP, dynamic tests under changing conditions depending on the heat load are also possible. For this purpose, appropriate temperature and heat load profiles can be specified.

The brine (water) water heat pumps are tested on a semi-automatic test bench. The performance data of the test bench are given in the following tables.

Performance data of the test rig

Heat source brine / water

Measured variable Unit min. range of application max. range of application
Volume flowm³/h 125
Brine temperature at inlet°C -15+40
max. pressure lossbar -4

Heat sink water

Measured variable Unit min. range of application max. range of application
Heating capacitykW0,525
Volume flowm³/h120
Water temperature at inlet°C +3+70
max. pressure lossbar -4

Electrical power measurement

Measured variable Unit min. range of application max. range of application
Power consumption    kW 0,530
FrequencyHzsupply frequency (50)supply frequency (50)
VoltageV 1~/2303~/400
CurrentA240

Your Request

Further Projects - Research and Development

Image

Cl.Ai.Co - Clever Air Components

Entwicklung eines innovativen Systems für eine energieeffiziente Gebäudeklimatisierung

Image

Laseroptical measurement

PIV and LDA / PDA

Image

Multifunctional electronic modules for cryogenic applications

Electronic with less wiring effort - more than 100 sensors via one feedthrough

Image

Certifiable connection types in cryogenics

Detachable and permanent connections, adhesive bond / form closure / force closure

Image

Combined building and system simulation

Scientific analysis of thermodynamic processes in buildings and its systems


Contact

Institut für Luft- und Kältetechnik - Gemeinnützige Gesellschaft mbH
Bertolt-Brecht-Allee 20, 01309 Dresden


Secretary to the Management

+49-351-4081-520

+49-351-4081-525

Image ISO 9001