Current research projects

Image Behavior of multiphase cryogenic fluids
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Mass Spectrometer
Image Reduction of primary noise sources of fans
Image Calibration leak for the water bath leak test
Image Non- invasive flow measurements
Image Investigation of material-dependent parameters
Image Cold meter
Image Breakthrough Sensor for Adsorption Filters (BelA)
Image Verification of storage suitability of cryo tubes
Image Ionocaloric cooling
Image Preformance measurements of heat exchangers
Image Multifunctional electronic modules for cryogenic applications
Image Optimizing HVAC operation with machine learning
Image High Capacity Pulse Tube Cooler
Image Filter Tests

You are here:  Home /  Research and Development


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects - Research and Development

Image

Reducing the filling quantity

How much refrigerant must be filled?

Image

Performance tests of condensing units

Does your condensing unit perform well?

Image

State of system and failure analyses

Cause of the failure unknown?

Image

Thermostatic Expansion Valves

Does the TXV function correctly?

Image

Testzentrum PLWP at ILK Dresden

Test Fluid-Energy Machines and Components