Aktuelle Forschungsprojekte

Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Low Temperature Tribology
Image Calibration leak for the water bath leak test
Image Testzentrum PLWP at ILK Dresden
Image Pulse-Tube-Refrigerator with sealed compressor
Image Solar Cooling
Image Optimizing HVAC operation with machine learning
Image Corrosion inhibitor for ammonia absorption systems
Image Modular storage system for solar cooling
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Range of services laboratory analyses
Image Cryogenic liquid piston pumps for cold liquefied gases like LIN, LOX, LHe, LH2, LNG, LAr
Image Verification of storage suitability of cryo tubes
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Measurement of insulated packaging
Image Laseroptical measurement

You are here:  Home /  Testing Equipment


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects - Testing Equipment

Image

Swirl-free on the move...

...with a contra-rotating fan

Image

Cold meter

The fast way to refrigerating capacity

Image

Innovative small helium liquefier

Liquefaction rates from 10 to 15 l/h

Image

Micro fluidic expansion valve

for increasing of the efficiency of small and compact cooling units