Current research projects

Image Development of a Cryogenic Magnetic Air Separation Unit
Image CO₂ GAS HYDRATES FOR SUSTAINABLE ENERGY AND COOLING SOLUTIONS
Image Low temperature – test facilities
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Test method for high - temperature heat pump - oils
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Testing of mobile leak detectors according to DIN EN 14624
Image Corrosion inhibitor for ammonia absorption systems
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Micro heat exchangers in refrigeration
Image Ice Slurry Generation
Image Low Temperature Measuring Service
Image Cryostats, Non-Metallic and Metallic
Image Combined building and system simulation
Image Software for technical building equipment
Image Ionocaloric cooling

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects

Image

Hybrid- Fluid for CO2-Sublimation Cycle

Cryogenic cooling by CO2 sublimation

Image

Energy efficiency consulting - cogeneration systems

How efficient is my refrigeration system?

Image

Cold meter

The fast way to refrigerating capacity

Image

Optimizing HVAC operation with machine learning

Intelligent control of HVAC systems – high comfort with low energy demand

Image

Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)

Linking the entire life cycle of a multi-functional air handling unit