Current research projects

Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Low noise and non metallic liquid-helium cryostat
Image Calibration leak for the water bath leak test
Image Investigation of coolants
Image Ionocaloric cooling
Image Air-water heat pumps
Image Innovative small helium liquefier
Image Investigation of material-dependent parameters
Image Test rigs for refrigeration and heat pump technology
Image Micro heat exchangers in refrigeration
Image Innovative Parahydrogen Generator Based on Magnets
Image Performance tests of condensing units
Image Pulse-Tube-Refrigerator with sealed compressor
Image Service offer for Leak Detection and Tightness Test
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image Cryostats, Non-Metallic and Metallic

You are here:  Home /  Testing Equipment


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects - Testing Equipment

Image

Micro fluidic expansion valve

for increasing of the efficiency of small and compact cooling units

Image

Solar Cooling

Solar Cooling with Photovoltaic

Image

Low noise and non metallic liquid-helium cryostat

Low-noise Magnetic Field Cryostat for SQUID-Applications

Image

Cryostats, Non-Metallic and Metallic