Aktuelle Forschungsprojekte

Image Calibration leak for the water bath leak test
Image IO-Scan - Integral measuring optical scanning method
Image Hydrogen and methane testing field at the ILK
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Practical training, diploma, master, bachelor
Image Test rigs for refrigeration and heat pump technology
Image Swirl-free on the move...
Image Service offer for Leak Detection and Tightness Test
Image Cold meter
Image Corrosion inhibitor for ammonia absorption systems
Image Lifetime prediction of hermetic compressor systems
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Multifunctional electronic modules for cryogenic applications
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image Testzentrum PLWP at ILK Dresden
Image High Capacity Pulse Tube Cooler

You are here:   /  Home


Low Temperature Measuring Service

Industry and R&D

Dr. rer. nat. Matthias Schneider

+49-351-4081-5126

Measurement of Thermal Properties at Low Temperatures

The cool down to cryogenic temperature causes thermal stress within the structure of components or complete devices. Furthermore thermal material properties could change crucial.

Samples can be proved down to 10 K via temperature cycling tests and/or measurements of the thermal conductivity, the coefficient of thermal expansion (also as integral for large sample dimensions) and the heat capacity. An experimental station with optimised conditions for measuring the thermal conductivity of different materials is under construction.

Thermal Tests (Cycling)

IndicatorMinimalMaximal
Cool down rate25 K/h200 K/min
Cool down cycles1Customer preference
Measuring accuracy1 %5 %
 Temperature range80 K (5 K)450 K
Sample preparationCustomer material
Sample dimensionup toØ 400 mm x 550 mm
other  dimenions on request

Thermal Conductivity

IndicatorMinimalMaximal
Measuring range10-2 W/(m K)103 W/(m K)
Measuring accuracy1 %5 %
 Temperature range10 K350 K
Sample preparationCustomer material
Sample dimensionup toØ 60 mm x 20 mm
other  dimenions on request

Heat Capacity

IndicatorMinimalMaximal
Measuring range10 J/(kg K)10 J/(kg K)
Measuring accuracy1 %5 %
Temperature range10 K350 K
Sample preparationCustomer material
Sample dimensionup to150 x 150 x 150 mm3
other  dimenions on request

Coefficient of Thermal Expansion

IndicatorMinimalMaximal
Measuring range10-6 K-110-4 K-1
Measuring accuracy0.1 %5 %
Temperature range10 K350 K
Sample preparationCustomer material
Sample dimensionup to200 x 200 x 200 mm3
other  dimenions on request

Your Request

Further Projects

Image

All-in-one device for freeze-drying and production of biomaterial

with automated freezing and sterilisation option

Image

Investigation according to DIN EN ISO 14903

These tests according to DIN EN ISO 14903 are possible at ILK Dresden