Aktuelle Forschungsprojekte

Image Solar Cooling
Image Humidifier System for High-Purity Gases
Image Helium extraction from natural gas
Image Performance tests of refrigerant compressors
Image Practical training, diploma, master, bachelor
Image Influenced melting point of water by magnetic field
Image Calibration of Low Temperature Sensors
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Low noise and non metallic liquid-helium cryostat
Image Lifetime prediction of hermetic compressor systems
Image Investigation according to DIN EN ISO 14903
Image Verification of storage suitability of cryo tubes
Image Combined building and system simulation
Image All-in-one device for freeze-drying and production of biomaterial
Image Certifiable connection types in cryogenics
Image Energy efficiency consulting - cogeneration systems

You are here:   /  Home


Development of a Cryogenic Magnetic Air Separation Unit

Federal Ministry for Economic Affairs and Climate Action

02/2022-07/2024

Erik Neuber

+49-351-4081-5122

Oxygen Enrichment by Applied Cryogenic Magnetohydrodynamics

Nowadays, for oxygen enrichment from air, various commercial options are available, among other things, pressure swing adsorption, cryogenic rectification, and membranes. Although well-established, most of these methods do have a relative high specific energy demand for small-to-medium production rates (in this context: 0–100 TPD (tonnes per day) of oxygen) and relative high purities (at least 90 vol% of oxygen) [1].

To close this gap, ILK Dresden intends to develop and optimise an efficient cryogenic magnetic air separation unit that enables oxygen enrichment by means of OGMS (open-gradient magnetic separation). Motivated by provisional first-shot experiments, for a first setup, the following parameters are being targeted:

  • Operating pressure: 1–3 bar(a);
  • Degree of purity: 95 vol% oxygen;
  • Production rate: 5 standard l/min oxygen;
  • Specific energy demand: 160–180 kWh/t oxygen;
  • Required time for start-up: 30–60 min;
  • Continuous operation;
  • Less maintenance requirements than pressure swing adsorption;
  • Comparable space requirements as pressure swing adsorption.

Moreover, based on the experimental results, the scalability of the system for higher production rates of up to 100 TPD oxygen shall be analysed.

For this patented technology, ILK Dresden is looking for industrial partners that have interest in financial participation, specific applications, or further developments.

Granted Patent:

DE 10 2021 109 146 A1


Your Request