Aktuelle Forschungsprojekte

Image High temperature heat pump
Image Laseroptical measurement
Image Tribological investigations of oil-refrigerant-material-systems
Image Test rigs for refrigeration and heat pump technology
Image Calibration of Low Temperature Sensors
Image IN-SITU SWELLING BEHAVIOUR OF POLYMER MATERIALS IN FLAMMABLE FLUIDS
Image Performance tests of refrigerant compressors
Image Multifunctional electronic modules for cryogenic applications
Image Lifetime prediction of hermetic compressor systems
Image State of system and failure analyses
Image Low Temperature Tribology
Image Testzentrum PLWP at ILK Dresden
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Filter Tests
Image Micro fluidic expansion valve
Image Cold meter

You are here:   /  Home


Certifiable connection types in cryogenics

BMWI

Dr. Andreas Kade

+49-351-4081-5117

Detachable and permanent connections, adhesive bond / form closure / force closure

The applications of cryogenic and vacuum technology impose special requirements on connection technologies. To determine the appropriate connections the application parameters such as temperature, vacuum and pressure, leak rate, materials, surface properties, radiation resistance, magnetic permeability etc. should be considered.

Connection technologies even if not being part of a standardized process more often have to be subject of a certification or qualification due to increasing quality requirements, e.g. pressure equipment directive 2014/68/EU. Therefore adequate designing and testing is necessary.

Innovations

The intended innovations relate to complete cryogenic systems considering the process chain from room temperature to low temperature range regarding the respectively required specifications. 

  • Development of application-related connection technologies with defined requirements and derived mechanical limit values 
  • Examination of existing connection technologies regarding applicability and further development towards secure and functional technologies
  • Evaluation and definition of application limits to aim for a feasible certification and the subsequent conformity with European guidelines

Project objectives

  • Application-related examination of various connection technologies
  • Further development and adaptation of existing connections to the requirements of cryogenic and vacuum technology
  • Examination on composite materials 
  • Examination on component geometries and their influence on the connection
  • Determination of process parameters (e.g. TIG welding, brazing,...) 
  • Determination of test limit values, especially for test specimens deviating from standards
  • Calculation according to common standards, simulation (FEM, ...) and testing
  • Realization and certification of selected connection technologies

Your Request

Further Projects

Image

Cool Up

Upscaling Sustainable Cooling

Image

Ionocaloric cooling

Ionocaloric solid-liquid phase cooling process

Image

Low temperature – test facilities

thermal cycling tests at very low temperatures