Aktuelle Forschungsprojekte

Image Tribological investigations of oil-refrigerant-material-systems
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image High Capacity Pulse Tube Cooler
Image Micro heat exchangers in refrigeration
Image Ionocaloric cooling
Image Panel with indirect evaporative cooling via membrane
Image IO-Scan - Integral measuring optical scanning method
Image Corrosion inhibitor for ammonia absorption systems
Image Energy efficiency consulting - cogeneration systems
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Filter Tests
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image Influenced melting point of water by magnetic field
Image Cryostats, Non-Metallic and Metallic
Image Performance tests of condensing units
Image Air-flow test rig for fan characteristic measurement

You are here:  Home /  Research and Development


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.