Current research projects

Image IO-Scan - Integral measuring optical scanning method
Image Low noise and non metallic liquid-helium cryostat
Image Ionocaloric cooling
Image All-in-one device for freeze-drying and production of biomaterial
Image Service offer for Leak Detection and Tightness Test
Image Multifunctional electronic modules for cryogenic applications
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Low Temperature Tribology
Image Calibration of Low Temperature Sensors
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Reduction of primary noise sources of fans
Image Humidifier System for High-Purity Gases
Image Software for technical building equipment
Image Brine (water)-water heat pump
Image Software modules
Image Innovative Manufacturing Technologies for Cryosorption Systems

You are here:  Home /  Testing Equipment


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects - Testing Equipment

Image

Multifunctional electronic modules for cryogenic applications

Electronic with less wiring effort - more than 100 sensors via one feedthrough

Image

Swirl-free on the move...

...with a contra-rotating fan

Image

Cold meter

The fast way to refrigerating capacity

Image

Innovative small helium liquefier

Liquefaction rates from 10 to 15 l/h