Current research projects

Image ZeroHeatPump
Image Corrosion inhibitor for ammonia absorption systems
Image Range of services laboratory analyses
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Filter Tests
Image Service offer for Leak Detection and Tightness Test
Image Energy efficiency consulting - cogeneration systems
Image Test rigs for refrigeration and heat pump technology
Image Thermostatic Expansion Valves
Image Influenced melting point of water by magnetic field
Image Low Temperature Measuring Service
Image Calibration of Low Temperature Sensors
Image Panel with indirect evaporative cooling via membrane
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects

Image

Development of a Cryogenic Magnetic Air Separation Unit

Oxygen Enrichment by Applied Cryogenic Magnetohydrodynamics

Image

Software for test rigs

Individual software for complex tests and evaluation

Image

Brine (water)-water heat pump

Test according DIN EN 14511 and 14825

Image

High temperature heat pump

Using waste heat from industrial processes

Image

Air-water heat pumps

Test according DIN EN 14511 and 14825