Current research projects

Image Testzentrum PLWP at ILK Dresden
Image Air-water heat pumps
Image Corrosion inhibitor for ammonia absorption systems
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Computational fluid dynamics CFD
Image Micro fluidic expansion valve
Image IO-Scan - Integral measuring optical scanning method
Image Investigation according to DIN EN ISO 14903
Image Calibration leak for the water bath leak test
Image All-in-one device for freeze-drying and production of biomaterial
Image Calibration of Low Temperature Sensors
Image Production of novel barrier layers on polymer materials to reduce hydrogen permeation
Image Low Temperature Tribology
Image Software for technical building equipment
Image Electrical components in refrigeration circuits

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³