Current research projects

Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Non- invasive flow measurements
Image Test method for high - temperature heat pump - oils
Image Investigation of coolants
Image Electrical components in refrigeration circuits
Image Combined building and system simulation
Image Filter Tests
Image Hydrogen and methane testing field at the ILK
Image Brine (water)-water heat pump
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Calibration leak for the water bath leak test
Image Reduction of primary noise sources of fans
Image Intelligent innovative power supply for superconducting coils
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Behavior of multiphase cryogenic fluids
Image Development of a Cryogenic Magnetic Air Separation Unit

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request