Current research projects

Image Investigation of materials
Image Innovative small helium liquefier
Image Testing of mobile leak detectors according to DIN EN 14624
Image CO₂ GAS HYDRATES FOR SUSTAINABLE ENERGY AND COOLING SOLUTIONS
Image Testzentrum PLWP at ILK Dresden
Image IO-Scan - Integral measuring optical scanning method
Image Calibration of Low Temperature Sensors
Image Cryogenic liquid piston pumps for cold liquefied gases like LIN, LOX, LHe, LH2, LNG, LAr
Image Brine (water)-water heat pump
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Test method for high - temperature heat pump - oils
Image Low noise and non metallic liquid-helium cryostat
Image Investigation of material-dependent parameters
Image Service offer for Leak Detection and Tightness Test
Image Innovative Parahydrogen Generator Based on Magnets
Image Non- invasive flow measurements

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request