Aktuelle Forschungsprojekte

Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Corrosion inhibitor for ammonia absorption systems
Image Ionocaloric cooling
Image Non- invasive flow measurements
Image Thermostatic Expansion Valves
Image Cryostats, Non-Metallic and Metallic
Image Investigation according to DIN EN ISO 14903
Image Performance tests of refrigerant compressors
Image Filter Tests
Image Behavior of multiphase cryogenic fluids
Image Performance tests of condensing units
Image Low temperature – test facilities
Image Service offer for Leak Detection and Tightness Test
Image Reducing the filling quantity
Image State of system and failure analyses
Image Multifunctional electronic modules for cryogenic applications

You are here:   /  Home


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects

Image

Development of a Cryogenic Magnetic Air Separation Unit

Oxygen Enrichment by Applied Cryogenic Magnetohydrodynamics

Image

Software for test rigs

Individual software for complex tests and evaluation

Image

Brine (water)-water heat pump

Test according DIN EN 14511 and 14825

Image

High temperature heat pump

Using waste heat from industrial processes

Image

Air-water heat pumps

Test according DIN EN 14511 and 14825