Current research projects

Image ZeroHeatPump
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Lifetime prediction of hermetic compressor systems
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image 3D - Air flow sensor
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Test procedures for electrical components
Image Refrigerants, lubricants and mixtures
Image Performance tests of refrigerant compressors
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Investigation according to DIN EN ISO 14903
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Service offer for Leak Detection and Tightness Test
Image Ionocaloric cooling
Image Optimizing HVAC operation with machine learning

You are here:   /  Home


Thermostatic Expansion Valves

Industry

Dr.-Ing. Matthias Böhm

+49-351-4081-5211

Does the TXV function correctly?

We support the industry in the development of energy-efficient vapor-compression refrigeration system and compression heat pumps.

The ILK Dresden offers the following services for you:

The ILK Dresden have been active in the field of performance testing of refrigeration compressors and condensing units for over 20 years.

Our offer includes also the investigation of thermostatic expansion valves (TEV) with external temperature sensors.

The tests of the TEV are carried out on a suitable refrigeration cycles (fig. 2), taking into account the following standards

  • AHRI 750 (2007),
  • ANSI/ ASHRAE 17 (2008, fig. 1) and
  • ASERCOM-Statement (9_GER_Dimensionierung_von_TXV_2011)

Current calibrations of the measuring systems are a matter of course.

The test can be carried out with the refrigerants R134a, R404A, R407A, R407C, R407F, R448A, R513A, R452A up to a mass flow of 400 kg/h (~20 kW for R134a).

Additional offerings

The following influences on the valve behaviour can be investigated

  • run-in period
  • hysteresis
  • transient tests / time constant
  • pressure losses
  • sub cooling
  • ambient temperature
  • critical pressure ratio

Your Request

Further Projects

Image

Hydrogen and methane testing field at the ILK

Simultaneously pressures up to 1,000 bar, temperatures down to –253°C

Image

Low noise and non metallic liquid-helium cryostat

Low-noise Magnetic Field Cryostat for SQUID-Applications

Image

Cryostats, Non-Metallic and Metallic

position indenpendent, highest endurance, tiltable for liquid helium and liquid nitrogen

Image

Calibration of Low Temperature Sensors

According to the comparative measurement method