Aktuelle Forschungsprojekte

Image Range of services laboratory analyses
Image Reducing the filling quantity
Image Multifunctional electronic modules for cryogenic applications
Image All-in-one device for freeze-drying and production of biomaterial
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Energy efficiency consulting - cogeneration systems
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Measurements on ceiling mounted cooling systems
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Software for test rigs
Image Testing of mobile leak detectors according to DIN EN 14624
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image Low Temperature Measuring Service
Image Calibration of Low Temperature Sensors
Image Reduction of primary noise sources of fans
Image Air-flow test rig for fan characteristic measurement

You are here:   /  Home


Service offer for Leak Detection and Tightness Test

Dipl.-Ing. (FH) René Seidel

+49-351-4081-5428

Use our experience

Service offer for leak detection and tightness test

Leak detection and tightness tests are interesting for many areas of technology, e.g. vacuum technology, refrigeration and construction of chemical plants, reservoir plants, power stations or tanks. Depending on the task we offer:

  • Development of tightness test technologies (according to DIN EN 1779, DIN EN 13185)
  • Coarse leak detection: vacuum pressure rise test, pressure drop test and ultrasonic test
  • Bubble detection: immersion or application of liquid (method C1, C2 according to DIN EN 1779)
  • Vacuum tightness test with helium gas detector (method A3, B2.1 according to DIN EN 1779)
  • Fine leak detection with selective gas detectors (method B4 according to DIN EN 1779)
  • Tightness tests with vacuum chamber or flexible hood (method B3 according to DIN EN 1779)
  • Helium tightness test of components up to 180bar overpressure

Our special offer for refrigeration applications

  • Construction of customization tightness test benches
  • Development and construction of strength test stands and plants for test gas recovery
  • Leak detection / tightness test when using HFCs, HFC mixtures, HFO and natural refrigerants such as hydrocarbons, NH3 and CO2
  • Leak detection / tightness test with forming gas
  • Tightness test with mass spectrometer measurement technique for helium and higher masses
  • Lectures and trainings at the ILK or on the spot (also offered in cooperation with the Bundesfachschule Kälte-Klima-Technik Maintal and Niedersachswerfen)
  • Support of small trade and industry regarding (regular) tightness tests of refrigeration plants including processing of problems
  • Performance tests of mobile leak detectors and room monitoring devices (according to DIN EN 14624)
  • Delivery of special test leaks for mobile leak detectors (link order sheet and flyer) and individual test leaks according to customer requirements
  • Qualification of leak tightness of components and connections (according to DIN EN 16084 resp. DIN EN ISO 14903)

Technological basis at the ILK

  • State-of-the-art measurement technology. Gas detectors, pressure and temperature measuring instruments, calibration standards
  • Mobile testing devices for measurements on the spot
  • Tightness test laboratory
  • Participation in the special committee for tightness testing of DGZfP
  • Longtime experiences from research projects and industry tasks