Current research projects

Image Software modules
Image Optimizing HVAC operation with machine learning
Image Low Temperature Measuring Service
Image Test rigs for refrigeration and heat pump technology
Image Air-flow test rig for fan characteristic measurement
Image Refrigerants, lubricants and mixtures
Image Measurements on ceiling mounted cooling systems
Image IO-Scan - Integral measuring optical scanning method
Image Pulse-Tube-Refrigerator with sealed compressor
Image Verification of storage suitability of cryo tubes
Image Electrical components in refrigeration circuits
Image Investigation of materials
Image Cryostats, Non-Metallic and Metallic
Image Corrosion inhibitor for ammonia absorption systems
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Energy efficiency consulting - cogeneration systems

You are here:   /  Home


Development of a Cryogenic Magnetic Air Separation Unit

Federal Ministry for Economic Affairs and Climate Action

02/2022-07/2024

Erik Neuber

+49-351-4081-5122

Oxygen Enrichment by Applied Cryogenic Magnetohydrodynamics

Nowadays, for oxygen enrichment from air, various commercial options are available, among other things, pressure swing adsorption, cryogenic rectification, and membranes. Although well-established, most of these methods do have a relative high specific energy demand for small-to-medium production rates (in this context: 0–100 TPD (tonnes per day) of oxygen) and relative high purities (at least 90 vol% of oxygen) [1].

To close this gap, ILK Dresden intends to develop and optimise an efficient cryogenic magnetic air separation unit that enables oxygen enrichment by means of OGMS (open-gradient magnetic separation). Motivated by provisional first-shot experiments, for a first setup, the following parameters are being targeted:

  • Operating pressure: 1–3 bar(a);
  • Degree of purity: 95 vol% oxygen;
  • Production rate: 5 standard l/min oxygen;
  • Specific energy demand: 160–180 kWh/t oxygen;
  • Required time for start-up: 30–60 min;
  • Continuous operation;
  • Less maintenance requirements than pressure swing adsorption;
  • Comparable space requirements as pressure swing adsorption.

Moreover, based on the experimental results, the scalability of the system for higher production rates of up to 100 TPD oxygen shall be analysed.

For this patented technology, ILK Dresden is looking for industrial partners that have interest in financial participation, specific applications, or further developments.

Granted Patent: