Current research projects

Image Filter Tests
Image Thermal engines
Image Multifunctional electronic modules for cryogenic applications
Image State of system and failure analyses
Image Performance tests of condensing units
Image Modular storage system for solar cooling
Image Computational fluid dynamics CFD
Image Measurements on ceiling mounted cooling systems
Image Cryostats, Non-Metallic and Metallic
Image Software for test rigs
Image Combined building and system simulation
Image Investigation of material-dependent parameters
Image Innovative small helium liquefier
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Brine (water)-water heat pump
Image Test rigs for refrigeration and heat pump technology

You are here:   /  Home


Certifiable connection types in cryogenics

BMWI

Dr. Andreas Kade

+49-351-4081-5117

Detachable and permanent connections, adhesive bond / form closure / force closure

The applications of cryogenic and vacuum technology impose special requirements on connection technologies. To determine the appropriate connections the application parameters such as temperature, vacuum and pressure, leak rate, materials, surface properties, radiation resistance, magnetic permeability etc. should be considered.

Connection technologies even if not being part of a standardized process more often have to be subject of a certification or qualification due to increasing quality requirements, e.g. pressure equipment directive 2014/68/EU. Therefore adequate designing and testing is necessary.

Innovations

The intended innovations relate to complete cryogenic systems considering the process chain from room temperature to low temperature range regarding the respectively required specifications. 

  • Development of application-related connection technologies with defined requirements and derived mechanical limit values 
  • Examination of existing connection technologies regarding applicability and further development towards secure and functional technologies
  • Evaluation and definition of application limits to aim for a feasible certification and the subsequent conformity with European guidelines

Project objectives

  • Application-related examination of various connection technologies
  • Further development and adaptation of existing connections to the requirements of cryogenic and vacuum technology
  • Examination on composite materials 
  • Examination on component geometries and their influence on the connection
  • Determination of process parameters (e.g. TIG welding, brazing,...) 
  • Determination of test limit values, especially for test specimens deviating from standards
  • Calculation according to common standards, simulation (FEM, ...) and testing
  • Realization and certification of selected connection technologies

Your Request

Further Projects

Image

State of system and failure analyses

Cause of the failure unknown?

Image

Thermostatic Expansion Valves

Does the TXV function correctly?

Image

Testzentrum PLWP at ILK Dresden

Test Fluid-Energy Machines and Components

Image

Performance tests of refrigerant compressors

Does your compressor perform well?

Image

Swirl-free on the move...

...with a contra-rotating fan