Current research projects

Image Energy efficiency consulting - cogeneration systems
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Air-water heat pumps
Image High Capacity Pulse Tube Cooler
Image Cryogenic liquid piston pumps for cold liquefied gases like LIN, LOX, LHe, LH2, LNG, LAr
Image Service offer for Leak Detection and Tightness Test
Image Humidifier System for High-Purity Gases
Image High temperature heat pump
Image Air-flow test rig for fan characteristic measurement
Image Reducing the filling quantity
Image Non- invasive flow measurements
Image Influenced melting point of water by magnetic field
Image Reduction of primary noise sources of fans
Image Helium extraction from natural gas
Image Testzentrum PLWP at ILK Dresden
Image Pulse-Tube-Refrigerator with sealed compressor

You are here:   /  Home


Low temperature – test facilities

Industry and research instituts

Gunar Schroeder

+49-351-4081-5129

thermal cycling tests at very low temperatures

Parts and components of machines such as satellites or space telescopes are subject to mechanical stress. In addition to the mechanical stress, the temperatures at which these components are used also have an influence on their strength and thus also on their lifetime. In the area of materials research, material aging and especially for space applications with the very high temperature changes that occur in a vacuum, temperature change tests are essential. These tests normally are combined with subsequent strength testing. With the knowledge gained, e.g. how the component strength changes due to extreme temperature changes, the components can be optimally designed with regard to the special requirements for reliability and minimum weight.

A test chamber has been build up at the ILK Dresden specifically for such temperature change tests. With the help of this thermal cycling chamber, parts or components can be exposed to changing temperatures for different durations. The temperatures can be specified in the range of 20 – 363 K for defined time intervals. The temperature gradients, performing the change from the lowest temperature to the highest temperature or reverse can also be specified in a range. Using a programmable electronic control, temperature profiles can be defined and run through in automated test operation over several hours to several days.

Sample limits Parameter
Temperature range 20 K ... 363 K / -253°C ... +90°C / -423°F ... 194°F
Temperature stability ± 1 K
Dimension, length x width 0,95 m x 0,6 m / 3 ft x 2 ft
Mass up to 30 kg / 66 lb

 


Your Request

Further Projects

Image

Low Temperature Tribology

Tribological studies at cryogenic temperatures

Image

Investigation of coolants

Secondary loop refrigerants

Image

Refrigerants, lubricants and mixtures

Determination of working fluid properties

Image

Reduction of primary noise sources of fans

...using numerical and experimental methods with contra-rotating axial fan

Image

Software for technical building equipment

Design cooling load and energetic annual simulation (VDI 2078, VDI 6007, VDI 6020)