Current research projects

Image Energy efficiency consulting - cogeneration systems
Image Behavior of multiphase cryogenic fluids
Image Software for technical building equipment
Image Investigation according to DIN EN ISO 14903
Image Ionocaloric cooling
Image High temperature heat pump
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Innovative small helium liquefier
Image Combined building and system simulation
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Micro fluidic expansion valve
Image Tribological investigations of oil-refrigerant-material-systems
Image CO₂ GAS HYDRATES FOR SUSTAINABLE ENERGY AND COOLING SOLUTIONS
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Service offer for Leak Detection and Tightness Test
Image Measurements on ceiling mounted cooling systems

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects

Image

Low noise and non metallic liquid-helium cryostat

Low-noise Magnetic Field Cryostat for SQUID-Applications

Image

Cryostats, Non-Metallic and Metallic

position indenpendent, highest endurance, tiltable for liquid helium and liquid nitrogen

Image

Calibration of Low Temperature Sensors

According to the comparative measurement method

Image

High Capacity Pulse Tube Cooler

for Cryogenic High-Power Applications