Current research projects

Image Testing of mobile leak detectors according to DIN EN 14624
Image IO-Scan - Integral measuring optical scanning method
Image Innovative small helium liquefier
Image Modular storage system for solar cooling
Image Measurement of insulated packaging
Image Humidifier System for High-Purity Gases
Image Tribological investigations of oil-refrigerant-material-systems
Image Tensile and compression testing
Image CFE-Test of Cooker Hoods
Image Brine (water)-water heat pump
Image Reducing the filling quantity
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Thermal engines
Image 3D - Air flow sensor
Image Computational fluid dynamics CFD

You are here:   /  Home


IO-Scan - Integral measuring optical scanning method

INNO-KOM

02/2022 - 07/2024

M.Sc. Rebekka Grüttner

+49-351-4081-5314

IO-Scan

Development of a photometric measurement method for determining the air exchange rate in indoor areas

Motivation

  • Cost-effective, real-time assessment of indoor air quality in the form of air exchange rates
  • Verify and optimise the effectiveness of ventilation systems in occupied areas
  • Ability to evaluate aerosol reduction through the interaction of window ventilation, building ventilation system and mobile room air cleaners

Project Objective

  • Self-calibrating measuring system
  • Deviation from previous trace gas measurements should be within 10%.
  • Real-time results can detect and evaluate the influence of changes in the ventilation system during the measurement process
  • Intended measurement depth in the room: 1 m to 50 m

Solution Approach

  • The introduction of mist aerosols into the room air influences the light transmittance to be measured.
  • Transmittance of an air-aerosol mixture and use of measured transmittance to determine air exchange rate
  • Integral real-time optical measurement over individual indoor distances

[Translate to EN:] Ergebnisse / Aktueller Stand

[Translate to EN:]

[Translate to EN:]

[Translate to EN:]


Your Request

Further Projects

Image

Performance tests of condensing units

Does your condensing unit perform well?

Image

State of system and failure analyses

Cause of the failure unknown?

Image

Thermostatic Expansion Valves

Does the TXV function correctly?

Image

Testzentrum PLWP at ILK Dresden

Test Fluid-Energy Machines and Components

Image

Performance tests of refrigerant compressors

Does your compressor perform well?