Current research projects

Image Measurements on ceiling mounted cooling systems
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Micro heat exchangers in refrigeration
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Reducing the filling quantity
Image Solar Cooling
Image Certifiable connection types in cryogenics
Image Humidifier System for High-Purity Gases
Image IO-Scan - Integral measuring optical scanning method
Image 3D - Air flow sensor
Image Ionocaloric cooling
Image Performance tests of condensing units
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Electrical components in refrigeration circuits
Image Combined building and system simulation
Image Practical training, diploma, master, bachelor

You are here:   /  Home


Tensile and compression testing

Industry and research institutes

Gunar Schroeder

+49-351-4081-5129

Determination of yield strength, tensile strength and elongation at break

A tensile or compression test is a quasi-static, destructive test method for determining material characteristics such as yield strength, tensile strength and elongation at break. The specimen form and the procedure of such tests are standardized. The ISO 9862 standard defines the exact procedure and the measured variables to be recorded for metallic materials and the DIN 50125 standard defines the specimen shape and its production method. In addition, the arrangement can generally be used to record force-displacement curves with high accuracy.

To carry out the test, the specimens are clamped centrally in the grippers or positioned centrally between the compression plates. In the tensile test, the specimens are pulled apart in a defined manner. In the compression test, on the other hand, a compressive force is applied to the test specimen, e.g. rectangular prisms, cylinders or tubes, in a uniaxial stress state. In both tests, the force and change in length are recorded continuously and evaluated graphically. On request, the tensile and compression test can be carried out at very low temperatures.

Parameter Limit values samples
Materials foils, plastics, composites, metals
Typical dimension of plastic samples Lר: 200×10 mm (7.8"×0.4") or
L×W×H: 200×10×10 mm (7.8"×0.4"×0.4")
Measurement range of force and displacement ±5 kN (±1124 lbf), 400 mm (15.8")
Standardized testing force-distance, force-time, tension-extension

 