Current research projects

Image Cryostats, Non-Metallic and Metallic
Image Low noise and non metallic liquid-helium cryostat
Image Behavior of multiphase cryogenic fluids
Image High Capacity Pulse Tube Cooler
Image Multifunctional electronic modules for cryogenic applications
Image Influenced melting point of water by magnetic field
Image Measurement of insulated packaging
Image Cryogenic liquid piston pumps for cold liquefied gases like LIN, LOX, LHe, LH2, LNG, LAr
Image Investigation of coolants
Image Tribological investigations of oil-refrigerant-material-systems
Image Innovative small helium liquefier
Image Innovative Parahydrogen Generator Based on Magnets
Image Range of services laboratory analyses
Image Investigation of materials
Image Tensile and compression testing
Image Testing of mobile leak detectors according to DIN EN 14624

You are here:   /  Home


Tensile and compression testing

Industry and research institutes

Gunar Schroeder

+49-351-4081-5129

Determination of yield strength, tensile strength and elongation at break

A tensile or compression test is a quasi-static, destructive test method for determining material characteristics such as yield strength, tensile strength and elongation at break. The specimen form and the procedure of such tests are standardized. The ISO 9862 standard defines the exact procedure and the measured variables to be recorded for metallic materials and the DIN 50125 standard defines the specimen shape and its production method. In addition, the arrangement can generally be used to record force-displacement curves with high accuracy.

To carry out the test, the specimens are clamped centrally in the grippers or positioned centrally between the compression plates. In the tensile test, the specimens are pulled apart in a defined manner. In the compression test, on the other hand, a compressive force is applied to the test specimen, e.g. rectangular prisms, cylinders or tubes, in a uniaxial stress state. In both tests, the force and change in length are recorded continuously and evaluated graphically. On request, the tensile and compression test can be carried out at very low temperatures.

Parameter Limit values samples
Materials foils, plastics, composites, metals
Typical dimension of plastic samples Lר: 200×10 mm (7.8"×0.4") or
L×W×H: 200×10×10 mm (7.8"×0.4"×0.4")
Measurement range of force and displacement ±5 kN (±1124 lbf), 400 mm (15.8")
Standardized testing force-distance, force-time, tension-extension

 


Your Request