Aktuelle Forschungsprojekte

Image Innovative small helium liquefier
Image Measurements on ceiling mounted cooling systems
Image Software modules
Image Influenced melting point of water by magnetic field
Image Calibration of Low Temperature Sensors
Image Low noise and non metallic liquid-helium cryostat
Image Helium extraction from natural gas
Image Service offer for Leak Detection and Tightness Test
Image Non- invasive flow measurements
Image Micro fluidic expansion valve
Image Micro heat exchangers in refrigeration
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Low temperature – test facilities
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Ionocaloric cooling

You are here:   /  Home


Thermostatic Expansion Valves

Industry

Dr.-Ing. Matthias Böhm

+49-351-4081-5211

Does the TXV function correctly?

We support the industry in the development of energy-efficient vapor-compression refrigeration system and compression heat pumps.

The ILK Dresden offers the following services for you:

The ILK Dresden have been active in the field of performance testing of refrigeration compressors and condensing units for over 20 years.

Our offer includes also the investigation of thermostatic expansion valves (TEV) with external temperature sensors.

The tests of the TEV are carried out on a suitable refrigeration cycles (fig. 2), taking into account the following standards

  • AHRI 750 (2007),
  • ANSI/ ASHRAE 17 (2008, fig. 1) and
  • ASERCOM-Statement (9_GER_Dimensionierung_von_TXV_2011)

Current calibrations of the measuring systems are a matter of course.

The test can be carried out with the refrigerants R134a, R404A, R407A, R407C, R407F, R448A, R513A, R452A up to a mass flow of 400 kg/h (~20 kW for R134a).

Additional offerings

The following influences on the valve behaviour can be investigated

  • run-in period
  • hysteresis
  • transient tests / time constant
  • pressure losses
  • sub cooling
  • ambient temperature
  • critical pressure ratio

Your Request