Aktuelle Forschungsprojekte

Image Influenced melting point of water by magnetic field
Image Cryogenic liquid piston pumps for cold liquefied gases like LIN, LOX, LHe, LH2, LNG, LAr
Image OVERALL SYSTEM OPTIMIZATION OF REFRIGERATION PLANT SYSTEMS FOR ENERGY TRANSITION AND CLIMATE PROTECTION
Image Behavior of multiphase cryogenic fluids
Image Ionocaloric cooling
Image Lifetime prediction of hermetic compressor systems
Image Practical training, diploma, master, bachelor
Image Service offer for Leak Detection and Tightness Test
Image Pulse-Tube-Refrigerator with sealed compressor
Image Innovative Parahydrogen Generator Based on Magnets
Image Low Temperature Measuring Service
Image Range of services laboratory analyses
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Low Temperature Tribology
Image Heat2Power
Image Test rigs for refrigeration and heat pump technology

You are here:  Home /  Measurements and Tests


Measurement of insulated packaging

Industry

A. Illgen

+49-351-4081-5216

How efficient is my cool box?

Nowadays, more and more goods to be cooled, such as food or medicines, are being shipped. In order to ensure a continuous cold chain for these mostly small units, the goods are packed in insulated boxes without active cooling. In some cases, passive cold accumulators in the form of freezer packs are also packed.

We support the industry in the evaluation and continuous improvement of this packaging. Therfore we offer the following services:

  • Measurement of heat transition coefficient (k-Value) of the insulated boxes / containers according to DIN EN 17066 in suitable climate chambers.
  • Measurement to determine the maximum cooling time of the insulated boxes / containers with loading and freezer packs, if necessary.
  • Consulting to improve insulated boxes / containers and freezer packs.

All Measurements are carried out in close coordination with the costumer. Different calibrated measurement systems and data loggers are available. The measurements will be carried out at constant temperature or specified temperature profiles. Various packages according to DIN EN 62552 with gel filling are available for simulating the goods / loading of the insulated boxes. Thermal images can also be taken to identify thermal bridges.


Your Request

Further Projects - Measurements and Tests

Image

Corrosion inhibitor for ammonia absorption systems

An alternative to chromium(VI) compounds

Image

Brine (water)-water heat pump

Test according DIN EN 14511 and 14825

Image

Air-water heat pumps

Test according DIN EN 14511 and 14825

Image

Electrochemical decontamination of electrically conducting surfaces „EDeKo II“

Improvement of sanitary prevention by electrochemical decontamination