Current research projects

Image Modular storage system for solar cooling
Image All-in-one device for freeze-drying and production of biomaterial
Image IO-Scan - Integral measuring optical scanning method
Image Practical training, diploma, master, bachelor
Image Heat2Power
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Pulse-Tube-Refrigerator with sealed compressor
Image Test method for high - temperature heat pump - oils
Image Brine (water)-water heat pump
Image Cold meter
Image Air-water heat pumps
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Low Temperature Tribology
Image ZeroHeatPump

You are here:  Home /  Research and Development


Low temperature – test facilities

Industry and research instituts

Gunar Schroeder

+49-351-4081-5129

thermal cycling tests at very low temperatures

Parts and components of machines such as satellites or space telescopes are subject to mechanical stress. In addition to the mechanical stress, the temperatures at which these components are used also have an influence on their strength and thus also on their lifetime. In the area of materials research, material aging and especially for space applications with the very high temperature changes that occur in a vacuum, temperature change tests are essential. These tests normally are combined with subsequent strength testing. With the knowledge gained, e.g. how the component strength changes due to extreme temperature changes, the components can be optimally designed with regard to the special requirements for reliability and minimum weight.

A test chamber has been build up at the ILK Dresden specifically for such temperature change tests. With the help of this thermal cycling chamber, parts or components can be exposed to changing temperatures for different durations. The temperatures can be specified in the range of 20 – 363 K for defined time intervals. The temperature gradients, performing the change from the lowest temperature to the highest temperature or reverse can also be specified in a range. Using a programmable electronic control, temperature profiles can be defined and run through in automated test operation over several hours to several days.

Sample limits Parameter
Temperature range 20 K ... 363 K / -253°C ... +90°C / -423°F ... 194°F
Temperature stability ± 1 K
Dimension, length x width 0,95 m x 0,6 m / 3 ft x 2 ft
Mass up to 30 kg / 66 lb

 


Your Request

Further Projects - Research and Development

Image

Innovative small helium liquefier

Liquefaction rates from 10 to 15 l/h

Image

Filter Tests

INDUSTRIAL AND LABORATORY PRECIPITATORS

Image

Low Temperature Tribology

Tribological studies at cryogenic temperatures

Image

Refrigerants, lubricants and mixtures

Determination of working fluid properties

Image

Reduction of primary noise sources of fans

...using numerical and experimental methods with contra-rotating axial fan