Current research projects

Image Low Temperature Measuring Service
Image Low noise and non metallic liquid-helium cryostat
Image Influenced melting point of water by magnetic field
Image Solar Cooling
Image Intelligent innovative power supply for superconducting coils
Image High Capacity Pulse Tube Cooler
Image Measurements on ceiling mounted cooling systems
Image Breakthrough Sensor for Adsorption Filters (BelA)
Image High temperature heat pump
Image Investigation of materials
Image Mass Spectrometer
Image IO-Scan - Integral measuring optical scanning method
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Calibration of Low Temperature Sensors
Image Filter Tests
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)

You are here:  Home /  Research and Development


Low temperature – test facilities

Industry and research instituts

Gunar Schroeder

+49-351-4081-5129

thermal cycling tests at very low temperatures

Parts and components of machines such as satellites or space telescopes are subject to mechanical stress. In addition to the mechanical stress, the temperatures at which these components are used also have an influence on their strength and thus also on their lifetime. In the area of materials research, material aging and especially for space applications with the very high temperature changes that occur in a vacuum, temperature change tests are essential. These tests normally are combined with subsequent strength testing. With the knowledge gained, e.g. how the component strength changes due to extreme temperature changes, the components can be optimally designed with regard to the special requirements for reliability and minimum weight.

A test chamber has been build up at the ILK Dresden specifically for such temperature change tests. With the help of this thermal cycling chamber, parts or components can be exposed to changing temperatures for different durations. The temperatures can be specified in the range of 20 – 363 K for defined time intervals. The temperature gradients, performing the change from the lowest temperature to the highest temperature or reverse can also be specified in a range. Using a programmable electronic control, temperature profiles can be defined and run through in automated test operation over several hours to several days.

Sample limits Parameter
Temperature range 20 K ... 363 K / -253°C ... +90°C / -423°F ... 194°F
Temperature stability ± 1 K
Dimension, length x width 0,95 m x 0,6 m / 3 ft x 2 ft
Mass up to 30 kg / 66 lb

 


Your Request

Further Projects - Research and Development

Image

Innovative small helium liquefier

Liquefaction rates from 10 to 15 l/h

Image

Filter Tests

INDUSTRIAL AND LABORATORY PRECIPITATORS

Image

Low Temperature Tribology

Tribological studies at cryogenic temperatures

Image

Refrigerants, lubricants and mixtures

Determination of working fluid properties

Image

Reduction of primary noise sources of fans

...using numerical and experimental methods with contra-rotating axial fan