Aktuelle Forschungsprojekte

Image Filter Tests
Image Electrical components in refrigeration circuits
Image Reduction of primary noise sources of fans
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image High temperature heat pump
Image Influenced melting point of water by magnetic field
Image Calibration leak for the water bath leak test
Image Behavior of multiphase cryogenic fluids
Image High Capacity Pulse Tube Cooler
Image Low temperature – test facilities
Image Software modules
Image Low noise and non metallic liquid-helium cryostat
Image Modular storage system for solar cooling
Image Range of services laboratory analyses
Image Lifetime prediction of hermetic compressor systems

You are here:  Home /  Research and Development


Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K

Dr. rer. nat. Erik Neuber

+49-351-4081-5122

high performance efficiency, environmental friendliness, compactness, cost-effectiveness

The main objective of the R&D project is the development of a cryogenic cooling system capable of recondensing a gas stream of vaporized natural gas back to its liquid form or cooling and/or liquefying other gases to a temperature level of 77 K. The technical solutions for the development of the system aim to provide a number of advantages over existing systems: high performance efficiency, environmental friendliness, compactness, and cost-effectiveness.
The cryogenic refrigeration system will include several innovations and technical solutions:

  • Development of an innovative and cost-effective refrigeration source based on a mixed-refrigerant low-temperature cooler.
  • Detailed calculation and determination of innovative as well as adapted zeotropic refrigerant mixtures, which optimize the energy efficiency of the cooler with respect to its application and ensure environmental friendliness.
  • Determination of the optimal as well as adapted working parameters and dimensions of the cooler and its components with regard to its desired properties (efficiency, fire protection, etc.).

On the basis of the chosen principle of the cryogenic cooling system, a special Linde-Hampson refrigerant mixture cooler was designed, which works with zeotropic refrigerant mixtures and should achieve temperatures of ≤ 100 K, see Figure 1. Thermodynamic calculations of the circuit and the determination of the components of the working mixture and their composition were carried out. For this purpose multiparametric optimization methods as well as gradient methods with different calculation grids were used.
As functional model, a system was implemented which should enable the liquefaction of nitrogen via a second refrigerant circuit. This model was initially tested with simple standard refrigerants and multi-component refrigerant mixtures and works very reliably. The results obtained will be used in the next step to demonstrate the liquefaction of nitrogen.


Your Request

Further Projects - Research and Development

Image

Performance tests of condensing units

Does your condensing unit perform well?

Image

State of system and failure analyses

Cause of the failure unknown?

Image

Thermostatic Expansion Valves

Does the TXV function correctly?

Image

Testzentrum PLWP at ILK Dresden

Test Fluid-Energy Machines and Components

Image

Performance tests of refrigerant compressors

Does your compressor perform well?