Current research projects

Image Innovative Manufacturing Technologies for Cryosorption Systems
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Testzentrum PLWP at ILK Dresden
Image High temperature heat pump
Image Service offer for Leak Detection and Tightness Test
Image Micro heat exchangers in refrigeration
Image Ionocaloric cooling
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Thermostatic Expansion Valves
Image Heat2Power
Image Measurements on ceiling mounted cooling systems
Image 3D - Air flow sensor
Image Hydrogen and methane testing field at the ILK
Image Practical training, diploma, master, bachelor
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image Cryogenic liquid piston pumps for cold liquefied gases like LIN, LOX, LHe, LH2, LNG, LAr

You are here:   /  Home


Thermostatic Expansion Valves

3466

We support the industry in the development of energy-efficient vapor-compression refrigeration system and compression heat pumps.

The ILK Dresden offers the following services for you:

The ILK Dresden have been active in the field of performance testing of refrigeration compressors and condensing units for over 20 years.

Our offer includes also the investigation of thermostatic expansion valves (TEV) with external temperature sensors.

The tests of the TEV are carried out on a suitable refrigeration cycles (fig. 2), taking into account the following standards

  • AHRI 750 (2007),
  • ANSI/ ASHRAE 17 (2008, fig. 1) and
  • ASERCOM-Statement (9_GER_Dimensionierung_von_TXV_2011)

Current calibrations of the measuring systems are a matter of course.

The test can be carried out with the refrigerants R134a, R404A, R407A, R407C, R407F, R448A, R513A, R452A up to a mass flow of 400 kg/h (~20 kW for R134a).

Additional offerings

The following influences on the valve behaviour can be investigated

  • run-in period
  • hysteresis
  • transient tests / time constant
  • pressure losses
  • sub cooling
  • ambient temperature
  • critical pressure ratio