Current research projects

Image Service offer for Leak Detection and Tightness Test
Image Innovative Parahydrogen Generator Based on Magnets
Image Development of a Cryogenic Magnetic Air Separation Unit
Image IO-Scan - Integral measuring optical scanning method
Image High temperature heat pump
Image Reduction of primary noise sources of fans
Image Test method for high - temperature heat pump - oils
Image Computational fluid dynamics CFD
Image Pulse-Tube-Refrigerator with sealed compressor
Image Reducing the filling quantity
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Intelligent innovative power supply for superconducting coils
Image Verification of storage suitability of cryo tubes
Image Thermal engines
Image Performance tests of condensing units
Image Behavior of multiphase cryogenic fluids

You are here:  Home /  Research and Development


Low Temperature Tribology

Industry and R&D

Dipl.-Ing. Gunar Schroeder

+49-351-4081-5129

Tribological studies at cryogenic temperatures

For special applications at cryogenic temperatures the use of dry friction is necessary because the working temperatures are significant lower than the working range of liquid lubricants.

The ILK Dresden has extensive experience in the field of material testing at cryogenic temperatures and has developed a measuring system (from roomtemperature down to cryogenic temperatures) to determine the roughness and the coefficient of friction of different sliding material combinations.

The test stand consists of an experimental platform and a traversing mechanism with a force sensor, which is controlled via PC. The direct measurement of the friction force is carried out by the distance covered. Measurements can be performed down to −196 °C (lower temperatures on request). The cooling of the experimental platform and the samples is realised by a controlled liquid nitrogen heat exchanger/evaporator. Measurements are performed under an atmosphere of gaseous nitrogen to prevent the ingress of moisture. Thereby the experimental samples have no direct contact to liquid nitrogen. The uniform temperature distribution is measured by thermocouples, which are calibrated at the ILK Dresden.

Advantages: modular test setup which can be changed to specific requirements; adjustment of sample geometry and/or test track is possible.

Parameter

Measuring accuracyMeasuring range 0.4 N to 2 N≤ 1 % of measured value
Measuring range 2 N to 100 N≤ 0.5 % of measured value
Measuring range extendible up to 5 kN

Repeatability
(e.g. PTFE)

± 0.05 N respectively 1.5 % of coefficient of friction

Your Request

Further Projects - Research and Development