Current research projects

Image Optimizing HVAC operation with machine learning
Image Low noise and non metallic liquid-helium cryostat
Image Air-flow test rig for fan characteristic measurement
Image Measurements on ceiling mounted cooling systems
Image CFE-Test of Cooker Hoods
Image Low Temperature Measuring Service
Image Micro fluidic expansion valve
Image Cryogenic liquid piston pumps for cold liquefied gases like LIN, LOX, LHe, LH2, LNG, LAr
Image Multifunctional electronic modules for cryogenic applications
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Performance tests of condensing units
Image Investigation according to DIN EN ISO 14903
Image Micro heat exchangers in refrigeration
Image High temperature heat pump
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Test rigs for refrigeration and heat pump technology

You are here:  Home /  Testing Equipment


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects - Testing Equipment

Image

Breakthrough Sensor for Adsorption Filters (BelA)

Sensor system for detecting an imminent breakthrough in gas filtration

Image

Low temperature – test facilities

thermal cycling tests at very low temperatures

Image

All-in-one device for freeze-drying and production of biomaterial

with automated freezing and sterilisation option

Image

Corrosion inhibitor for ammonia absorption systems

An alternative to chromium(VI) compounds