Current research projects

Image Behavior of multiphase cryogenic fluids
Image Swirl-free on the move...
Image Low Temperature Measuring Service
Image Low temperature – test facilities
Image Intelligent innovative power supply for superconducting coils
Image Thermostatic Expansion Valves
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Humidifier System for High-Purity Gases
Image Cryostats, Non-Metallic and Metallic
Image Ice Slurry Generation
Image Energy efficiency consulting - cogeneration systems
Image Breakthrough Sensor for Adsorption Filters (BelA)
Image Lifetime prediction of hermetic compressor systems
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Measurement of insulated packaging
Image Hydrogen and methane testing field at the ILK

You are here:   /  Home


Calibration of Low Temperature Sensors

Industry and R&D

Dr. rer. nat. Matthias Schneider

+49-351-4081-5126

According to the comparative measurement method

Accurate and reliable measurements are the requirements for high-quality research and development or industrial production. Using the comparative measurement method the following sensors can be calibrated:

  • Resistance Temperature Detectors (RTD) with positive temperature coefficient (like Platinum or Rhodium-Iron RTDs)
  • RTD with negative temperature coefficient (like Germanium or Cernox™ RTDs)
  • Diode and thermocouples.

With an automatic measuring station several temperatures according to a sample point table will be adjusted. The calibration is carried out with secondary thermometers that are calibrated by an authority. Furthermore a fix point check with LHe or LN2 will be performed. In addition, a calbriated Cernox sensor is available for measurements in the low temperature range. The measuring facility allows the calibration of about 30 sensors at once. There are continuous extensions for different sensor types.

Parameter

IndicatorMinimalMaximal
Measuring range1.5 K350 K
Measuring accuracy5 mK (1.5 ... 4.2 K)50 mK (80 ... 350 K)
Sample dimensioncommon sensor packages
Sample preparationnot necessary

Your Request

Further Projects

Image

Thermal engines

Power Generation from Waste Heat

Image

Helium extraction from natural gas

Innovative solutions for helium extraction

Image

Ice Slurry Generation

Using Direct Evaporation

Image

Pulse-Tube-Refrigerator with sealed compressor

for mobil use in the hydrogen technology

Image

Low Temperature Measuring Service

Measurement of Thermal Properties at Low Temperatures