Current research projects

Image Investigation according to DIN EN ISO 14903
Image Solar Cooling
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Thermostatic Expansion Valves
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image Measurement of insulated packaging
Image Air-flow test rig for fan characteristic measurement
Image Test procedures for electrical components
Image Electrical components in refrigeration circuits
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image 3D - Air flow sensor
Image ZeroHeatPump
Image Optimizing HVAC operation with machine learning
Image Low temperature – test facilities
Image Reduction of primary noise sources of fans
Image Calibration of Low Temperature Sensors

You are here:   /  Home


Certifiable connection types in cryogenics

BMWI

Dr. Andreas Kade

+49-351-4081-5117

Detachable and permanent connections, adhesive bond / form closure / force closure

The applications of cryogenic and vacuum technology impose special requirements on connection technologies. To determine the appropriate connections the application parameters such as temperature, vacuum and pressure, leak rate, materials, surface properties, radiation resistance, magnetic permeability etc. should be considered.

Connection technologies even if not being part of a standardized process more often have to be subject of a certification or qualification due to increasing quality requirements, e.g. pressure equipment directive 2014/68/EU. Therefore adequate designing and testing is necessary.

Innovations

The intended innovations relate to complete cryogenic systems considering the process chain from room temperature to low temperature range regarding the respectively required specifications. 

  • Development of application-related connection technologies with defined requirements and derived mechanical limit values 
  • Examination of existing connection technologies regarding applicability and further development towards secure and functional technologies
  • Evaluation and definition of application limits to aim for a feasible certification and the subsequent conformity with European guidelines

Project objectives

  • Application-related examination of various connection technologies
  • Further development and adaptation of existing connections to the requirements of cryogenic and vacuum technology
  • Examination on composite materials 
  • Examination on component geometries and their influence on the connection
  • Determination of process parameters (e.g. TIG welding, brazing,...) 
  • Determination of test limit values, especially for test specimens deviating from standards
  • Calculation according to common standards, simulation (FEM, ...) and testing
  • Realization and certification of selected connection technologies

Your Request

Further Projects

Image

Cryostats, Non-Metallic and Metallic

position indenpendent, highest endurance, tiltable for liquid helium and liquid nitrogen

Image

Calibration of Low Temperature Sensors

According to the comparative measurement method

Image

High Capacity Pulse Tube Cooler

for Cryogenic High-Power Applications

Image

Thermal engines

Power Generation from Waste Heat