Current research projects

Image Investigation according to DIN EN ISO 14903
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Humidifier System for High-Purity Gases
Image Heat2Power
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Tensile and compression testing
Image Hydrogen and methane testing field at the ILK
Image Intelligent innovative power supply for superconducting coils
Image Electrical components in refrigeration circuits
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image 3D - Air flow sensor
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image ZeroHeatPump
Image Pulse-Tube-Refrigerator with sealed compressor
Image Influenced melting point of water by magnetic field
Image Verification of storage suitability of cryo tubes

You are here:   /  Home


Low temperature – test facilities

Industry and research instituts

Gunar Schroeder

+49-351-4081-5129

thermal cycling tests at very low temperatures

Parts and components of machines such as satellites or space telescopes are subject to mechanical stress. In addition to the mechanical stress, the temperatures at which these components are used also have an influence on their strength and thus also on their lifetime. In the area of materials research, material aging and especially for space applications with the very high temperature changes that occur in a vacuum, temperature change tests are essential. These tests normally are combined with subsequent strength testing. With the knowledge gained, e.g. how the component strength changes due to extreme temperature changes, the components can be optimally designed with regard to the special requirements for reliability and minimum weight.

A test chamber has been build up at the ILK Dresden specifically for such temperature change tests. With the help of this thermal cycling chamber, parts or components can be exposed to changing temperatures for different durations. The temperatures can be specified in the range of 20 – 363 K for defined time intervals. The temperature gradients, performing the change from the lowest temperature to the highest temperature or reverse can also be specified in a range. Using a programmable electronic control, temperature profiles can be defined and run through in automated test operation over several hours to several days.

Sample limits Parameter
Temperature range 20 K ... 363 K / -253°C ... +90°C / -423°F ... 194°F
Temperature stability ± 1 K
Dimension, length x width 0,95 m x 0,6 m / 3 ft x 2 ft
Mass up to 30 kg / 66 lb

 


Your Request

Further Projects

Image

Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)

Linking the entire life cycle of a multi-functional air handling unit

Image

Software modules

Software for properties of refrigerants

Image

Verification of storage suitability of cryo tubes

Artificial aging of primary packaging for biobanking applications

Image

Preformance measurements of heat exchangers

Is the heat exchanger properly sized?

Image

Innovative small helium liquefier

Liquefaction rates from 10 to 15 l/h