Current research projects

Image Performance tests of condensing units
Image IO-Scan - Integral measuring optical scanning method
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image Breakthrough Sensor for Adsorption Filters (BelA)
Image Multifunctional electronic modules for cryogenic applications
Image Lifetime prediction of hermetic compressor systems
Image Pulse-Tube-Refrigerator with sealed compressor
Image Investigation of materials
Image Practical training, diploma, master, bachelor
Image Mass Spectrometer
Image Measurement of insulated packaging
Image Investigation of material-dependent parameters
Image Testing of mobile leak detectors according to DIN EN 14624
Image Helium extraction from natural gas
Image Computational fluid dynamics CFD
Image Service offer for Leak Detection and Tightness Test

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request