Current research projects

Image Hydrogen and methane testing field at the ILK
Image Testing of mobile leak detectors according to DIN EN 14624
Image Heat2Power
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Investigation of materials
Image Solar Cooling
Image High temperature heat pump
Image Pulse-Tube-Refrigerator with sealed compressor
Image Helium extraction from natural gas
Image Non- invasive flow measurements
Image Panel with indirect evaporative cooling via membrane
Image Software for test rigs
Image Investigation according to DIN EN ISO 14903
Image Micro heat exchangers in refrigeration
Image Air-flow test rig for fan characteristic measurement
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request