Current research projects

Image Non- invasive flow measurements
Image Test method for high - temperature heat pump - oils
Image Investigation of material-dependent parameters
Image Low temperature – test facilities
Image Micro fluidic expansion valve
Image Tensile and compression testing
Image Test procedures for electrical components
Image Practical training, diploma, master, bachelor
Image Investigation of coolants
Image Test rigs for refrigeration and heat pump technology
Image Mass Spectrometer
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image CFE-Test of Cooker Hoods
Image State of system and failure analyses
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Preformance measurements of heat exchangers

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request