Current research projects

Image Cryostats, Non-Metallic and Metallic
Image Tribological investigations of oil-refrigerant-material-systems
Image Innovative Parahydrogen Generator Based on Magnets
Image Calibration leak for the water bath leak test
Image Brine (water)-water heat pump
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Cool Up
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Computational fluid dynamics CFD
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Reducing the filling quantity
Image Service offer for Leak Detection and Tightness Test
Image Performance tests of refrigerant compressors
Image Influenced melting point of water by magnetic field
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Ionocaloric cooling

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects

Image

Investigation of material-dependent parameters

Investigation of the permeation behavior

Image

Cool Up

Upscaling Sustainable Cooling

Image

Breakthrough Sensor for Adsorption Filters (BelA)

Sensor system for detecting an imminent breakthrough in gas filtration

Image

Ionocaloric cooling

Ionocaloric solid-liquid phase cooling process

Image

Low temperature – test facilities

thermal cycling tests at very low temperatures