Current research projects

Image Investigation of coolants
Image Brine (water)-water heat pump
Image Micro fluidic expansion valve
Image Testing of mobile leak detectors according to DIN EN 14624
Image Practical training, diploma, master, bachelor
Image Laseroptical measurement
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Preformance measurements of heat exchangers
Image Verification of storage suitability of cryo tubes
Image Test rigs for refrigeration and heat pump technology
Image Testzentrum PLWP at ILK Dresden
Image Low noise and non metallic liquid-helium cryostat
Image Test method for high - temperature heat pump - oils
Image Modular storage system for solar cooling
Image IO-Scan - Integral measuring optical scanning method
Image Investigation according to DIN EN ISO 14903

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request