Image Optimizing HVAC operation with machine learning
Image ZeroHeatPump
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Air-water heat pumps
Image Software for test rigs
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Low noise and non metallic liquid-helium cryostat
Image State of system and failure analyses
Image Service offer for Leak Detection and Tightness Test
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Micro fluidic expansion valve
Image Tribological investigations of oil-refrigerant-material-systems
Image Breakthrough Sensor for Adsorption Filters (BelA)
Image Micro heat exchangers in refrigeration
Image Certifiable connection types in cryogenics
Image Range of services laboratory analyses

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects

Image

Thermostatic Expansion Valves

Does the TXV function correctly?

Image

Testzentrum PLWP at ILK Dresden

Test Fluid-Energy Machines and Components

Image

Performance tests of refrigerant compressors

Does your compressor perform well?

Image

Swirl-free on the move...

...with a contra-rotating fan

Image

Measurement of insulated packaging

How efficient is my cool box?