Image Investigation of coolants
Image High Capacity Pulse Tube Cooler
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Test rigs for refrigeration and heat pump technology
Image Test procedures for electrical components
Image Innovative Parahydrogen Generator Based on Magnets
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Certifiable connection types in cryogenics
Image Micro heat exchangers in refrigeration
Image Practical training, diploma, master, bachelor
Image Service offer for Leak Detection and Tightness Test
Image Pulse-Tube-Refrigerator with sealed compressor
Image Electrical components in refrigeration circuits
Image Thermostatic Expansion Valves
Image Verification of storage suitability of cryo tubes

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-627

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects

Image

Thermal engines

Power Generation from Waste Heat

Image

Helium extraction from natural gas

Innovative solutions for helium extraction

Image

Ice Slurry Generation

Using Direct Evaporation

Image

Pulse-Tube-Refrigerator with sealed compressor

for mobil use in the hydrogen technology

Image

Low Temperature Measuring Service

Measurement of Thermal Properties at Low Temperatures


Contact

Institut für Luft- und Kältetechnik - Gemeinnützige Gesellschaft mbH
Bertolt-Brecht-Allee 20, 01309 Dresden


Secretary to the Management

+49-351-4081-520

+49-351-4081-525

Image ISO 9001
Bild Zuse Mitglied Bild SIG